Common questions about AeroBarrier, the sealant and what to expect on installation day.

Do you service my area?

We serve California from San Diego to just north of the San Francisco Bay Area, including Los Angeles, Orange County and the Inland Empire, as well as Las Vegas and the surrounding area in Southern Nevada. See our service area.

At what stage of construction is AeroBarrier applied?

AeroBarrier can be installed at two stages: after rough-in and before insulation (right after spray foam, if any is used), or after drywall is installed and before finishes. With an unvented attic or no attic (such as a flat roof), you can choose either stage; a vented attic means the post-drywall stage. See the install requirements for each stage.

Can AeroBarrier be applied in an occupied or finished home?

We generally do not seal finished or occupied homes; the process is designed for new construction and complete remodels before finishes are installed. We can seal attics and crawl spaces of existing homes in certain situations.

If I use AeroBarrier, can I skip spray foam?

AeroBarrier is an air barrier, not insulation, so it doesn't replace the thermal role of spray foam. It does mean spray foam isn't needed as the interior air barrier. Where spray foam is used, AeroBarrier works with it to reach very tight targets. Note that unvented attics, cathedral ceilings and flat roofs typically still call for spray foam below the roof deck or rigid foam above it to manage condensation.

What is the sealant?

A waterborne acrylic that has long been used as a fluid-applied air barrier. AeroBarrier's X1 sealant is GREENGUARD Gold certified for low chemical emissions, is low VOC, and has been tested to ASTM standards and NFPA 285 for fire spread, smoke production, adhesion, antifungal properties and tensile strength.

Is it safe to breathe during application?

No. Anyone entering the space during sealing wears personal protective equipment. After sealing, the building is aired out for 30 minutes and is then safe to enter without protective gear.

Is the sealant safe inside a home?

Yes. AeroBarrier's X1 sealant is GREENGUARD Gold certified, a standard that also covers use in schools and healthcare facilities.

How long does it take?

Prep and sealing usually take two to three days on site, and other trades can keep working during prep. The sealing itself typically takes one to two hours. Very tight targets, such as Passive House or Zero Energy Ready Home, can take longer.

How soon can work resume?

The building is aired out for 30 minutes after sealing by opening doors and windows with the fan running. Work can resume as soon as the equipment is removed and the 30 minutes have passed.

How much does AeroBarrier cost?

Pricing is based on square footage and the airtightness level you choose, with three options on every proposal. The factors that affect cost are explained on our cost page.

What size leaks will it seal?

Gaps as small as a human hair and up to ½ inch wide. Aerosol sealing is especially effective on narrow gaps and tiny holes that are impractical to find or seal by hand.

What needs to be protected?

Very little at the insulation or drywall stage. Walls and windows do not need covering. Designed openings such as ducts, vents, electrical boxes and plumbing penetrations are covered before sealing, along with any finished horizontal surfaces.

Can sealing be done in cold weather?

The process needs temperature control while the building is pressurized. An outdoor temperature of 40°F or above is ideal. Sealing below 40°F is possible but may require additional preparation.

How long does the seal last?

In third-party lab testing, AeroBarrier withstood a simulated 50-year durability test with little or no loss of seal.

How is leakage measured?

With a standard calibrated blower door, the same equipment used for code compliance testing (ASTM E779 and RESNET procedures). Leakage is measured continuously during sealing.

How tight can a building get?

AeroBarrier can seal to whatever level the building is designed for, from just meeting energy code to below the Passive House standard of 0.6 ACH50. Very tight buildings need planned mechanical ventilation, such as an HRV or ERV.

Is AeroBarrier required by code?

In California, Title 24 does not require a tested airtightness level for single-family homes; a verified reduction in air leakage is an optional compliance credit under the performance approach. In Southern Nevada, energy code requires a blower-door test. See for builders.

Have another question? Contact us.

Request a proposal.

Provide the project's square footage, location and construction stage. We will respond with a written proposal presenting Good, Better and Best options.